2 Damp Buildings Almost all buildings experience excessive moisture, leaks, or flooding at some point. If dampness-related problems are to be prevented, it is essential to understand their causes. From a technologic viewpoint, one must under- stand the sources and transport of moisture in buildings, which depend on the design, operation, maintenance, and use of buildings in relation to exter- nal environmental conditions such as climate, soil properties, and topogra- phy. From a societal viewpoint, it is necessary to understand how construc- tion, operation, and maintenance practices may lead to dampness problems. The interactions among moisture, materials, and environmental conditions in and outside a building determine whether the building may become a source of potentially harmful dampness-related microbial and chemical exposures. Therefore, an understanding of the relationship of building moisture to mi- crobial growth and chemical emissions is also critical. This chapter addresses those issues to the extent that present scientific knowledge allows. It starts with a description of how and where buildings become wet; reviews the signs of dampness, how dampness is measured, and what is known about its prevalence and characteristics, such as sever- ity, location, and duration; discusses the risk factors for moisture problems; reviews how dampness influences indoor microbial growth and chemical emissions; catalogs the various agents that may be present in damp environ- ments; and addresses the influence of building materials on microbial growth and emissions. The chapter does not review effects of building dampness that are unrelated to indoor air quality or health. However, dampness problems 29

OCR for page 29
30 DAMP INDOOR SPACES AND HEALTH often cause building materials to decay or corrode, to become structurally weakened or lose their thermal capacity, and thus to reduce their useful life. Dampness also causes building materials and furnishings to develop an unacceptable appearance. The societal cost of such structural and visual effects of dampness may be high. As discussed below, there is no single, generally accepted term for referring to "dampness" or "damp indoor spaces." This chapter and the remainder of the report adopts the terminology of the research being cited or uses the default term "dampness." MOISTURE DEFINITIONS1 Studies use various qualitative terms to denote the presence of excess moisture in buildings. These include dampness, condensation, building damp- ness, visible dampness, damp patches, damp spots, water collection, water ponding, and moisture problem. Dampness--however it is expressed--is used to signify a wide array of signs of moisture damage of variable spatial extent and severity. It may represent visual observations of current or prior moisture (such as water stains or condensation on windows), observed microbial growth, measurement of high moisture content of building materials, mea- surement of high relative humidity in the indoor air, moldy or musty odors, and other signs that can be associated with excess moisture in a building. Some studies make separate observations of dampness and mold, and both observed dampness and visible mold have been weakly associated with mea- sured concentrations of fungi (Verhoeff et al., 1992). Chapter 3 discusses the various signs and measurements of dampness, moisture, or mold that have been used in studies and lists several examples. Numerous technical terms are also used to describe characteristics of moisture and moisture physics, including absorption, adsorption, desorp- tion, diffusion, capillary action, capillary height, convection, dew point, partial pressure, and water vapor permeability. A complete discussion of all the terms is beyond the scope of this study, but some that are used in the report are defined below. The amount of water present in a substance is expressed in relation to its volume (kg/m3), or to its oven-dry weight (kg/kg). The former is referred to as moisture content (MC), and the latter as percentage moisture content (%-MC). MC is directly proportional to %-MC and to the density of the substance (Bjrkholtz, 1987). 1Material in this section and later in the chapter has been adapted or excerpted from a dissertation by Dr. Ulla Haverinen-Shaughnessy (Haverinen, 2002) that was written under the supervision of one of the committee members. It is used here with the permission of the author.

OCR for page 29
DAMP BUILDINGS 31 Relative humidity (RH) is the existing water vapor pressure of the air, expressed as a percentage of the saturated water vapor pressure at the same temperature. RH reflects both the amount of water vapor in air and the air temperature. For example, if the temperature of a parcel of air is decreased but no water is removed, the RH will increase. If the air is cooled suffi- ciently, a portion of the gaseous water vapor in the air will condense, producing liquid water. The highest temperature that will result in conden- sation is called the "dewpoint temperature." "Humidity ratio" is another technical term used to characterize the moisture content of air. The humid- ity ratio of a parcel of air equals the mass or weight of water vapor in the parcel divided by the mass or weight of dry (moisture-free) air in the parcel. Humidity ratio, unlike RH, is independent of air temperature. The indoor outdoor humidity ratio can be used to estimate the rate of interior water vapor generation, or more qualitatively to indicate if a building has sources. Water generation rate can be computed from a moisture mass balance equation; however, the rate of outdoor air ventilation must be known. If the building has a dehumidifier or an air conditioner that dehumidifies, the rate of water removal via this device must be factored. Sorption and desorp- tion of water and from indoor surfaces also complicates the estimation of the internal water vapor generation rate. Monthly mean water activity level has been proposed as a metric for evaluating whether mold growth will occur on surfaces of newly-designed buildings (TenWolde and Rose, 1994) but there is reason to be skeptical about its practicality because the level varies throughout a building and is not easily measured at all relevant locations (for example, in wall cavities). The temperature of air and materials in a building varies spatially; therefore, RH also varies spatially. In the winter for example, the tempera- ture of the interior surface of a window or wall will normally be less that the temperature of air in the center of a room. Air in contact with the window or wall will cool to below the central room temperature, increasing the local relative humidity. If the surface has a temperature below the dewpoint temperature of adjacent air, water vapor will condense on the surface, producing liquid water. Without a source to moisten building material continuously, the MC of the material depends on temperature and the RH of the surrounding air. The RH of the atmosphere in equilibrium with a material that has a par- ticular MC is known as the equilibrium relative humidity (ERH) (Oliver, 1997). Different materials have different distributions of pore size and degrees of hygroscopicity so materials that have the same ERH may have different MC. For example, at an ERH of 80%, the MC for mineral wool is about 0.3 kg/m3, for concrete can be 80 kg/m3, and for wood is about 90 kg/m3 (Nevander and Elmarsson, 1994).

OCR for page 29
32 DAMP INDOOR SPACES AND HEALTH MOISTURE DYNAMICS IN BUILDINGS-- HOW BUILDINGS GET WET Water exists in three states: solid (ice), liquid, and gas (water vapor). The molecules in liquid water and water vapor move freely; molecules in ice are bound into a crystal matrix and are unable to move except to vibrate. Liquid water is a cohesive fluid; when it interacts with other materials, it is affected by forces that originate in the new material. If a drop attaches to a surface that has a strong affinity for water, like wood, it will spread out across the surface. The attraction may be great enough that water will run along the bottom of a horizontal material--a roof truss, for example--until it comes to an air gap or a downward projection where gravity pulls it away from the surface and it falls. Many building materials are porous, and the size of the pores affects their permeability. If the pores are small enough to keep both liquid water clusters and water vapor molecules from passing, the material is imperme- able; metal foils are examples of such materials. Materials with slightly larger pores (building papers like Tyvek and builders felt) will shed liquid water but be relatively permeable to water vapor. If the material has pores that are large enough for tiny clusters of liquid water to enter, it will be permeable to both liquid water and water vapor. As a result of intermolecu- lar forces, liquid water is drawn into the pores of such materials by capil- lary suction. Water drawn in that way is said to be absorbed by the porous material. Water migration through porous materials is a complex interac- tion of forces. Water molecules clinging to the surface of a solid material are bound to that surface by intermolecular forces. They cannot move about as freely as liquid water molecules or water vapor molecules and are in what is sometimes referred to as the adsorbed state. Water must accumu- late on surfaces to a depth of four or five molecules before it begins to move freely as a liquid (Straube, 2001). Adsorbed water cannot be removed by drainage. In the adsorbed state, water molecules are less available for chemi- cal and biologic purposes than they are in a nonadsorbed state. It does not take a great deal of moisture to cause problems with sensi- tive materials like paper or composite wooden materials. Moisture sources in buildings include rainwater, groundwater, plumbing, construction mois- ture, water use, condensation, and indoor and outdoor humidity (Lstiburek, 2001; Straube, 2002). The first three are sources of liquid-water problems, construction moisture may result in both liquid-water and water-vapor problems, and condensation associated with humidity involves water vapor as well as liquid water. Moisture problems begin when materials stay wet long enough for microbial growth, physical deterioration, or chemical reac- tions to occur. Those may happen because of continual wetting or intermit- tent wetting that happens often enough to keep materials from drying. As

OCR for page 29
DAMP BUILDINGS 33 discussed below, the important moisture-related variables in determining whether fungal growth occurs are those which affect the rate of wetting and the rate of drying (Lstiburek, 2002a). The most damaging water leaks are those which are large enough to flood a building or small enough not to attract notice but large enough to wet or humidify a cavity space or material for a long time. Thus, the "best" leak is one that is large enough to be noticed right away but small enough that the wetting does not promote microbial growth or affect materials. Both floods and slow leaks can result in large areas of fungal growth. Condensation sometimes occurs over a large area and can also result in extensive mold growth. Rainwater and Groundwater Placing a building on a site does not change how much rain falls each year--it changes the path that rainwater takes on its journey through the hydrologic cycle. When building designs work properly, rainwater is col- lected and redirected so that it does not intrude into the buildings them- selves. When collection and redirection fail, rainwater wets buildings. Build- ings have been protected from rainwater for centuries by using gravity, air gaps, and moisture-insensitive materials to direct and drain water away from other materials that can be damaged by water through corrosion, microbial contamination, or chemical reaction (Lstiburek, 2001). Weak- ness in rainwater protection can be found in the detailing of the roof, walls, windows, doors, decks, foundation, and site. Rainwater leaks may take a long time to become noticeable because the water often leaks into cavities that are filled with porous insulation. Insulation may retain the water, keeping materials wet longer than would empty cavities. Many roofing materials are impermeable to liquid water and can be repeatedly wetted and dried without damage. Wooden shingles and thatched roofs are exceptions. They drain the bulk of rainwater away from the interior but also absorb some of it. An air gap beneath then forms a mois- ture or water break and allows drying of the shingle or thatch by evapora- tion from inner and outer surfaces. Roof leaks typically occur at joints and penetrations; parapet walls, curbs for roof-mounted equipment and sky- lights, intersections between roofs and walls, and roof drains are common leakage sites. These leaks are often the result of failures in design or of installation of flashings and moisture or water breaks. In climates that receive substantial snowfall, water can intrude through roofs as the result of melting snow. Ice dams occur when there is snow on a roof and roof temperatures reach 33F (1C) or higher at times when the outdoor air temperature is below freezing. Snow on the warm part of the roof melts and then follows the drainage path until it reaches roofing that is

OCR for page 29
34 DAMP INDOOR SPACES AND HEALTH chilled below freezing by outdoor air. The water then freezes on this part of the roof and causes ice dams and icicles. Aggravating conditions for ice dams include sources of heat that warm snow-covered sheathing (air leaks and conductive heat loss from the building, recessed lighting fixtures in insulated ceilings, and uninsulated chimneys passing through attics) and valley roofs, which may collect water from a large surface area and drain it to one small location. Several design approaches are available for prevent- ing ice dams: Air-seal and heavily insulate the top of the building so that escaping heat does not reach the roofing. Ventilate the roof sheathing from underneath with outdoor air. (In combination with the air sealing and insulation, this keeps roofing cold, so melting does not occur or is minimized to rates that do not result in ice problems). Avoid heat sources in the vented attic or vent bays (for example, do not use recessed lights in insulated ceilings). Rainwater protection in walls is accomplished largely with three basic methods: massive moisture storage, drained cladding, and face-sealed clad- ding (Lstiburek, 2001; Straube and Burnett, 1997). Historically, walls ca- pable of massive moisture storage have been built of thick masonry materi- als (such as stone in older churches). Exterior detailing channels rainwater away from entry through such walls. The walls are also able to store a large amount of water in the adsorbed state, and their storage capacity is suffi- cient to accommodate rainwater wetting and drying cycles without causing problems.2 Rainwater intrusion problems occur in these walls when a path- way wicks water from the exterior to the interior, where moisture-sensitive materials are. Wooden structural members in masonry pockets, interior- finish walls made of wood or paper products, and furnishings composed of fabrics, adhesive, or composites are typical materials that may be affected by rainwater transported through walls by bridging or capillary suction. Cladding (a protective, insulating, or decorative covering) with air gaps and a drain plane is another historical answer to rainwater intrusion. A drained-cladding wall has an exterior finish that intercepts most of the rainwater that strikes it but is backed by an air gap and water-resistant drainage material to keep any water that gets past the cladding from enter- ing the wall beneath. Wooden clapboard, wooden shingles, board and bat, brick or block veneer, and traditional stucco are examples of cladding used in some climates in the United States that has historically been backed by an 2Condensation is not typically a problem, because, unlike many composite structures, such walls have relatively even distribution of water-vapor permeability.

OCR for page 29
DAMP BUILDINGS 35 air gap and drainage layer. Asphalt-impregnated felt paper, rosin paper, and high-permeability spun-plastic wraps are examples of materials that are used as the drainage layer. Foam board and foil-faced composite sheath- ing have also been used as drain planes beneath cladding (Lstiburek, 2000). The most frequent problems in these walls occur when moisture-sensitive sheathings--such as oriented strand board (OSB), plywood, and low- density fiberboards--are not protected by a drainage layer. Face-sealed walls are made of materials that are impermeable to water and are sealed at the joints with caulking or gaskets (Straube, 2001). Struc- tural glazing, metal-clad wooden or foam panels, and corrugated metal siding are examples of face-sealed cladding. The intention is to seal the joints between the panels well enough to prevent rainwater entry. Rainwa- ter intrusion occurs when the seals fail. Seals on some face-sealed walls need to be renewed every 45 years. The unavoidable weakness in rainwater protection for any wall is at the penetrations--windows, doors, light fixtures, the roofs of lower portions of the structure, decks, balconies, and porches. Rainwater leaks through poorly detailed, designed or installed flashing are most common. Common errors include failure to provide detailed instructions for flashing in construction documents, providing two-dimensional details for situations that require three-dimensional flashing, installing head flashings on top of building pa- per rather than installed underneath, and ignoring leaks in the window itself. Wall drain papers for windows must be installed in the same way that a raincoat is worn: over, not tucked into rain pants. Pan flashing beneath windows can prevent leaks, even of poorly installed windows, from wetting the wall below (Lstiburek, 2000). Foundations are typically protected from moisture problems by being constructed of materials that are resistant to water problems (stone, con- crete, and masonry) and having rainwater diverted away from them (Lstiburek, 2000, 2001). (In some old buildings, foundation structures could be constructed of wooden piers, which might have to be kept wet.) Exces- sive moisture in foundations is often the result of poorly managed rainwa- ter, but it may also result from groundwater intrusion, plumbing leaks, ventilation with hot humid air, or water in building materials (such as concrete) or in exposed soil (for example, saturated ground in a crawl space foundation). Rainwater is diverted by sloping the finish grade away from the building; rainwater and groundwater are diverted with subsoil drain- age. Drainage systems use stone pebbles, perforated drain pipe, sand and gravel, or proprietary drainage mats. Stone pebbles and perforated pipe are typically enclosed in a filter fabric to prevent clogging by fine soil particles. Below-grade foundations are coated with dampproofing to provide a capil- lary break. Water problems occur if rainwater collected on the roof is drained to the soil next to the foundation. This may happen if the site is

OCR for page 29
36 DAMP INDOOR SPACES AND HEALTH inadvertently contoured to collect rainwater and drain it into the building or if paving does so. Other problematic scenarios include a drainage pipe that is missing, is installed improperly, or does not drain to daylight or a sump pump; a drainage system that fills with silt carried by water percolat- ing through the soil and that then clogs; and a failure to install a capillary break, which would keep water from being wicked through concrete prod- ucts to the interior. Foundations may be slab on grade (or near grade), full basements, crawl spaces, piers, or a combination of these types. A slab-on-grade foun- dation consists of a concrete slab that constitutes the first floor of the building. The perimeter of the slab may be thickened and reinforced, or it may be bound by a perimeter wall that extends some distance into the soil. The most common water problems with slab-on-grade foundations are caused when rainwater from the roof or site wets the foundation and the water is wicked up through concrete to wall or flooring materials. If air ducts are placed in or beneath the slab, these may flood with poorly man- aged rainwater. A basement is made by excavating a large, pond-like hole in the ground and constructing walls and a floor in the bottom of the hole. A basement floor slab is wholly or partially below grade. Some basement floors are at grade on one side and below grade on another. A drainage system is placed on the bottom of the hole around the perimeter of the walls, and a capillary break in the form of stone pebbles or polyethylene film is placed beneath the floor. Walls are coated with some form of dampproofing to make a capillary break. Free-draining material is placed against the walls to divert water from the foundation into footing drains. Many potential causes of dampness problems in full basements result from vagaries of weather and defects in design, construction, and maintenance. Rainwater from the roof or site can easily saturate the soil near the foundation and make it more likely for liquid water to seep or run into the basement. A more subtle problem occurs when water wicking through the walls or slab evaporates into the basement, leaving the walls dry but over-humidifying the space. Placing framing, insulation, paneling, or gypsum board against a basement wall creates a microclimate between finished wall and basement wall. In fact, if the outdoor-air dewpoint is higher than the temperature in this space, ventilating air will add moisture to the cavity, not dry it and this can result in conditions favorable for microbial growth. A solution to this problem is to insulate the foundation wall on the outside. If the foundation is insulated on the inside, a material with high insulating value and low water-vapor permeability should be used; this will keep the warm humid basement air away from earth-chilled walls. Plastic foam insulation meets this criterion. If the water vapor permeability of the insulation is low enough, it will reduce drying from the foundation wall into the basement.

OCR for page 29
DAMP BUILDINGS 37 Placing insulation beneath the floor slab can prevent basement floors from "sweating" during hot humid weather because it thermally isolates the concrete slab from the cool earth below. A crawl space is constructed in the same way as a basement foundation except that it is shorter and often the floor is not covered by a concrete slab. Many crawl spaces have air vents through the walls intended to provide passive ventilation. Because crawl spaces are not intended for occupancy, drainage detailing around them is often lacking or poorly implemented. Rainwater intrusion is common. In addition, the floor is often exposed soil, which creates the potential for evaporation into the crawl space. Vents placed too close to the ground sometimes become rainwater intakes. When the outdoor-air dewpoint is higher than the temperature of the soil and foundation surfaces, ventilating air wets the crawl space rather than drying it (Kurnitski, 2000). Pier foundations (concrete or crushed-stone footings for posts that con- stitute the major structural support for a building) are the most resistant to rainwater problems. Piers extend from the ground to above the surface of the soil to support the lower structure of a building. The most common water problem for this type of foundation occurs if a depression in the ground beneath the structure collects water and exposes the underside of the building to prolonged high humidity. Plumbing and Wet Rooms Most water intentionally brought into buildings is used for drinking, cooking, or cleaning. The bulk of this water passes harmlessly through drains to public or private treatment and is then released to the hydrologic cycle from which it was diverted. The pathway followed by such water consists of pipes, tubs, sinks, showers, dish and clothes washers, driers, and ventilating air. Most of the materials used in the pathway are moisture- insensitive--able to withstand dampness without decomposing, dissolving, corroding, hydrolyzing, or supporting microbial growth. Moisture prob- lems occur when water leaks from pipes or from sinks, tub or shower enclosures, washing machines, ice machines, or other fixtures and appli- ances that have water hookups. Pipes leak when joints are incorrectly made or fail, water freezes in them, the pipe material corrodes or decomposes, or a screw or nail is driven through them. Joints may not be correctly soldered, gasketed, cemented, or doped. Water lines lose integrity when they are exposed to acidic or caustic water or--in the case of rubber or plastic lines to washing machines--the polymers break down from oxidation or ultraviolet (UV) light exposure. Corrosive water may lead to mold growth if a large number of small leaks result. Pipes in exterior walls or unheated crawl spaces or attics may freeze

OCR for page 29
38 DAMP INDOOR SPACES AND HEALTH and crack during subfreezing weather. A screw or nail driven through a pipe may not leak for some time, because the fastener seals the hole it made; after thermal expansion and contraction and corrosion work for some time, the pipe may begin to leak. Drains and water traps are vulnerable to leaks. Overflows and careless installation and renovation practices also contribute to problems with fix- tures and appliances that use water. The materials that surround tubs and showers--typically ceramic tiles and fiberglass panels--receive regular wet- tings. They must be constructed, sealed, and maintained to protect the wall and floor materials beneath them. As with rainwater protection, most prob- lems occur at the joints. Grout between ceramic tiles often does not ad- equately serve as a capillary break and water wicks through to the base. In ceramic tile surrounds with paper-covered gypsum board as the base, mold growth may occur beneath the grout and on the backside of the gypsum board where water wicks through the paper facing the wall cavity. Depending on the detailing, water may also be wicked through the gaps where fiberglass panels overlap and meet tubs or shower pans. The shower pan in stand-alone showers is another weak spot. Essentially, these are basins that must hold a small depth of water. Leaks are most common at the drain penetration. Pans that are constructed on site have more joints to leak than prefabricated pans that are molded into a single piece. Poorly designed, incorrectly installed, and carelessly used shower curtains and doors are another source of problems. Tub surrounds and shower enclo- sures can be constructed of materials that are poor substrates for fungal growth; for example, fiber-cement board, rather than paper-covered gyp- sum board, can be used as the base for ceramic tile. Such steps reduce, but do not eliminate, the possibility of microbial contamination. Construction Moisture In newly constructed buildings, a large amount of water vapor can be released by wet building materials such as recently cast concrete, and wet wooden products (Christian, 1994). Manufactured products that were origi- nally dry can become extensively wetted by exposure to rain during trans- portation, storage, and building construction. Case studies have attributed microbial contamination to the use of wet building materials or to wetting during building construction (Hung and Terra, 1996; Salo, 1999). Large areas of mold growth may occur when a floor enclosing an earth-floored crawl space is installed because the soil may be a reservoir of rainwater; the humidity in such a crawl space quickly becomes high when the floor deck is applied over moist earth. Floor decks made from OSB or plywood are vulnerable to mold growth during extended periods (23 days for OSB, 42 days for plywood) of RH greater than 95% (Doll, 2002).

OCR for page 29
DAMP BUILDINGS 39 Condensation and High Humidity Condensation necessarily involves water-vapor transport. The two im- portant variables for condensation are chilled surfaces and sources of water vapor. Materials chilled below the indoor or outdoor air temperature accu- mulate water molecules in the adsorbed state and are at risk for condensa- tion; those chilled below the local dew point will begin to accumulate liquid water. Porous materials can hold more water vapor than impermeable ones before liquid water appears. The combination of high RH in indoor or outdoor air and cooled building materials increases the risk of dampness problems and microbial growth. Even without condensation, the local RH of air at the surface of cool material can be very high, leading to high mois- ture content in the material. Figure 2-1 illustrates how much air needs to be cooled before the difference between the air temperature and dewpoint temperature equals zero and condensation occurs. Regardless of the initial air temperature, when the relative humidity is very high only a few degrees of cooling will result in condensation. For example, if the bulk of the air in a room has a RH of 80%, condensation will occur on a surface that is only about 7oF (4oC) cooler than the bulk room air temperature. Therefore, whenever cool 90 80 70 60 Tair-Tdewpoint (F) 90F 50 70F 50F 40 30 20 10 0 5 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%) FIGURE 2-1 The difference between air and dewpoint temperatures needed for condensation to occur, expressed as a function of relative humidity, for three in- door air temperatures.

OCR for page 29
DAMP BUILDINGS 79 Andersson MA, Mikkola R, Kroppenstedt RM, Rainey FA, Peltola J, Helin J, Sivonen K, Salkinoja-Salonen MS. 1998. The mitochondrial toxin produced by Streptomyces griseus strains isolated from an indoor environment is valinomycin. Applied and Environmental Microbiology 64(12):47674773. Angell W. 1988. Home Moisture Sources. Minnesota Cooperative Extension, Cold Climate Housing Information Center, University of Minnesota, St. Paul. Arruda LK, Platts-Mills TAE, Fox JW, Chapman MD. 1990. Aspergillus fumigatus. Allergen I, a major Ige-binding protein, is a member of the mitogillin family of cytotoxins. Jour- nal of Experimental Medicine 172(5):15291532. Aukrust L, Borch SM. 1979. Partial purification and characterization of two Cladosporium herbarum allergens. International Archives of Allergy and Applied Immunology 60(1): 6879. Batterman SA, Burge H. 1995. HVAC systems as emission sources affecting indoor air qual- ity--a critical review. International Journal of HVAC and Research 1(1):6180. Beguin H, Nolard N. 1994. Mould biodiversity in homes I. Air and surface analysis of 130 dwellings. Aerobiology 10:157166. Bencko V, Maelichercik J, Melichercikova V, Wirth Z. 1993. Microbial growth in spray humidifiers of health facilities. Indoor Air 3(1):2025. Bjrkholtz D. 1987. Lmp ja kosteus-rakennusfysiikka (Temperature- and moisture- building physics, in Finnish). Rakentajain Kustannus Oy, Vammalan Kirjapaino Oy, Vammala. Bornehag C-G, Blomquist G, Gyntelberg F, Jrvholm B, Malmberg P, Nordvall L, Nielsen A, Pershagen G, Sundell J. 2001. Dampness in buildings and health. Nordic interdiscipli- nary review of the scientific evidence on associations to "dampness" in buildings and health effects (NORDDAMP) Indoor Air 11:7286. Brattgjerd S, Evensen O, Lauve A. 1994. Effect of injected yeast glucan on the activity of macrophages in Atlantic salmon, Salmo salar L., as evaluated by in vitro hydrogen peroxide production and phagocytic capacity. Immunology 83(2):288294. Brennan T, Cummings J, Lstiburek J. 2002. Unplanned airflows and moisture problems. ASHRAE Journal 44(11):4452. Brunekreef B, Dockery DW, Speizer FE, Ware JH, Spengler JD, Ferris BG. 1989. Home dampness and respiratory morbidity in children. American Review of Respiratory Dis- eases 140:13631367. Burge HA, Hoyer ME, Solomon WR, Simmons EG, Gallup J. 1989. Quality control factors for Alternaria allergens. Mycotaxon 34(1):5563. Burge HA, Macher JM, Milton DK, Ammann HM. 1999. Data Evaluation. In: Bioaerosols: Assessment and Control, JM Macher, HA Ammann, HA Burge, DK Milton, PR Morey, eds. Cincinnati, OH: ACGIH. pp. 14-114-11. Buttner MP, Stetzenbach LD. 1993. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling. Applied and Environmental Microbiology 59(1):219226. Chang JCS, Foarde KK, Vanosdell DW. 1995. Growth evaluation of fungi (Penicillium and Aspergillus spp.) on ceiling tiles. Atmospheric Environment 29(17):23312337. Christian JE. 1994. Moisture sources. In: Moisture Control in Buildings. HR Trechsel, ed. Philadelphia, PA: ASTM. CMHC (Canadian Mortgage and Housing Corporation). 1996. Molds in Finished Base- ments. Ottawa, Ontario, Canada: Canadian Mortgage and Housing Corporation. Crameri R. 1998. Recombinant Aspergillus fumigatus allergens: from nucleotide sequences to clinical applications. International Archives of Allergy and Immunology 115(2):99114.

OCR for page 29
80 DAMP INDOOR SPACES AND HEALTH Cruz A, Saenz de Santamaria M, Martinez J, Martinez A, Guisantes J, Palacios R. 1997. Fungal allergens from important allergenic fungi imperfecti [Review]. Allergologia et Immunopathologia 25(3):153158. Daisy JM, Angell WJ. 1998. A Survey and Critical Review of the Literature on Indoor Air Quality, Ventilation, and Health Symptoms in Schools. Lawrence Berkeley National Laboratories. March. Dales RE, Miller D, McMullen E. 1997. Indoor air quality and health: validity and determi- nants of reported home dampness and moulds. International Journal of Epidemiology 26(1):120125. Dales RE, Miller D, White J. 1999. Testing the association between residential fungus and health using ergosterol measures and cough recordings. Mycopathologia 147(1):2127. DeKoster JA, Thorne PS. 1995. Bioaerosol concentrations in noncomplaint, complaint and intervention homes in the Midwest. American Industrial Hygiene Association Journal 56:573580. Demain AL. 1999. Pharmaceutically active secondary metabolites of microorganisms. Ap- plied Microbiology and Biotechnology 52:455463. Deuell B, Arruda LK, Hayden ML, Chapman MD, Platts-Mills TAE. 1991. Trichophyton tonsurans allergen I. Characterization of a protein that causes immediate but not de- layed hypersensitivity. Journal of Immunology 147(1):96101. Dharmage S, Bailey M, Raven J, Mitakakis T, Guest D, Cheng A, Rolland J, Thien F, Abramson M, Walters EH. 1999a. A reliable and valid home visit report for studies of asthma in young adults. Indoor Air 9:188192. Dharmage S, Bailey M, Raven J, Mitakakis T, Thien F, Forbes A, Guest D, Abramson M, Walters H. 1999b. Prevalence and residential determinants of fungi within homes in Melbourne, Australia. Clinical and Epidemiological Allergy 29:14811489. Dill I, Niggemann B. 1996. Domestic fungal viable propagules and sensitization in children with IgE mediated allergic diseases. Pediatric Allergy and Immunology 7(3):151155. Doll SC. 2002. Determination of Limiting Conditions for Fungal Growth in the Built Envi- ronment. Thesis (Doctor of Science). Harvard School of Public Health. Douwes J, Heederik D. 1997. Epidemiologic investigations of endotoxins. International Jour- nal of Occupational Environmental Health 3(1):S26S31. Douwes J, van der Sluis B, Doekes G, van Leusden F, Wijnands L, van Strien R, Verhoeff A, Brunekreef B. 1999. Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: relations with culturable fungi, reported home dampness, and respira- tory symptoms. Journal of Allergy and Clinical Immunology 103(3/1):494500. Engelhart S, Loock A, Skutlarek D, Sagunski H, Lommel A, Farber H, Exner M. 2002. Occurrence of toxigenic Aspergillus versicolor isolates and sterigmatocytins in carpet dust from damp indoor environments. Applied and Environmental Microbiology 68(8): 38863890. Engvall K, Norrby C, Norbck D. 2001. Asthma symptoms in relation to building dampness and odour in older multifamily houses in Stockholm. International Journal of Tubercu- losis and Lung Disease 5(5):468477. Evans J, Hyndman S, Steward-Brown S, Smith S, Petersen S. 2000. An epidemiological study of the relative importance of damp housing in relation to adult health. Journal of Epide- miology and Community Health 54:677686. Ezeonu IM, Noble JA, Simmons RB, Price DL, Crow SA, Ahearn DG. 1994. Effect of relative humidity on fungal colonization of fiberglass insulation. Applied and Environmental Microbiology 60(6):21492151. Fadel R, David B, Paris S, Guesdon JL. 1992. Alternaria spore and mycelium sensitivity in allergic patients: in vivo and in vitro studies. Annals of Allergy 69(4):329335.

OCR for page 29
DAMP BUILDINGS 81 Flannigan B, Miller JD. 2001. Microbial growth in indoor environments. In: Microorganisms in Home and Indoor Work Environments. Flannigan B, Samson RA, Miller JD, eds. New York : Taylor & Francis. pp. 3567. Fogelmark B, Sjostrand M, Rylander R. 1994. Pulmonary inflammation induced by repeated inhalations of beta(1,3)-D-glucan and endotoxin. International Journal of Experimental Pathology 75(2):8590. Gallup J, Kozak P, Cummins L, Gillman S. 1987. Indoor mold spore exposure: characteristics of 127 homes in Southern California with endogenous mold problems. Advances in Aerobiology 51:139142. Garrett MH, Rayment PR, Hooper MA, Abramson MJ, Hooper BM. 1998. Indoor airborne fungal spores, house dampness and associations with environmental factors and respira- tory health in children. Clinical and Experimental Allergy 28:459467. Grny RL, Reponen T, Willeke K, Schmechel D, Robine E, Boissier M, Grinshpun SA. 2002. Fungal fragments as indoor air biocontaminants. Applied and Environmental Microbiol- ogy 68(7):35223531. Grny RL, Mainelis G, Grinshpun SA, Willeke K, Dutkiewicz J, Reponen T. 2003. Release of Streptomyces albus propagules from contaminated surfaces. Environmental Research 91(1):4553. Gqaleni N, Smith JE, Lacey J, Gettinby G. 1997. Effects of temperature, water activity, and incubation time on production of aflatoxins and cyclopiazonic acid by an isolate of Aspergillus flavus in surface agar culture. Applied and Environmental Microbiology 63(3):10481053. Grant C, Hunter CA, Flannigan B, Bravery AF. 1989. The moisture requirements of moulds isolated from domestic dwellings. International Biodeterioration & Biodegradation 25: 259284. Gravesen S, Frinsvad JC, Samson RA. 1994. Microfungi. Munksgaard, Copenhagen, Den- mark. 168 p. Gravesen S, Nielsen PA, Iversen R, Nielsen KF. 1999. Microfungal contamination of damp buildings--examples of risk constructions and risk materials. Environmental Health Per- spectives 107(3):505508. Harriman LG, Brundrett GW, Kittler R. 2001. "The new ASHRAE design guide for humidity control in commercial buildings", Indoor Air Quality 2001--Moisture, Microbes, and Heath Effects: Indoor Air Quality and Moisture in Buildings Conference Papers. Haverinen U. 2002. Modeling moisture damage observations and their association with health symptoms. Doctoral dissertation. National Public Health Institute, Department of Envi- ronmental Health, Kuipio, Finland. http://www.ktl.fi/publications/2002/a10.pdf. Haverinen U, Husman T, Vahteristo M, Koskinen O, Moschandreas D, Nevalainen A, Pek- kanen J. 2001a. Comparison of two-level and three-level classifications of moisture- damaged dwellings in relation to health effects. Indoor Air 11(3):192199. Haverinen U, Vahteristo M, Husman T, Pekkanen J, Moschandreas D, Nevalainen A. 2001b. Characteristics of moisture damage in houses and their association with self-reported symptoms of the occupants. Indoor and Built Environment 10(2):8394. Haverinen U, Vahteristo M, Moschandreas D, Husman T, Nevalainen A, Pekkanen J. 2003. Knowledge-based and statistically modelled relationships between residential moisture dam- age and occupant reported health symptoms. Atmospheric Environment. 37(4):577585. Horner WE, Reese G, Lehrer SB. 1995. Identification of the allergen Psi c 2 from the basidi- omycete Psilocybe cubensis as a fungal cyclophilin. International Archives of Allergy and Immunology 107(13):298300. Hung LL, Terra JA. 1996. A case of fungal proliferation in a computer facility under con- struction: Part 1--The contamination. Proceedings of IAQ'96 Paths to Better Building Environments, K Teichman, ed. Atlanta, GA: ASHRAE.

OCR for page 29
82 DAMP INDOOR SPACES AND HEALTH Hunt DRG, Gidman AMIA. 1982. A national field survey of house temperatures. Building and Environment 17(2):102124. Hunter CA, Grant C, Flannigan B, Bravery AF. 1988. Mould in buildings: the air spora of domestic dwellings. International Biodeterioration 24:81101. Husman H. 1996. Health effects of indoor-air microorganisms. Scandinavian Journal of Work, Environment and Health 22:513. Huttunen K, Hyvrinen A, Nevalainen A, Komulainen H, Hirvonen MR. 2003. Production of proinflammatory mediators by indoor air bacteria and fungal spores in mouse and human cell lines. Environmental Health Perspectives 111(1):8592. Hyvrinen A. 2002. Characterizing moisture damaged buildings--environmental and biologi- cal monitoring. Academic Dissertation. Department of Environmental Sciences, Univer- sity of Kuopio, Kuopio, Finland, and the National Public Health Institute. Hyvrinen A, Meklin T, Vepslinen A, Nevalainen A. 2002. Fungi and actinobacteria in moisture-damaged building materials--concentrations and diversity. International Bio- deterioration & Biodegradation 49:2737. ICBO (International Conference of Building Officials). 2000. International Residence Code 2000. May. IOM (Institute of Medicine). 1993. Indoor Allergens: Assessing and Controlling Adverse Health Effects. Washington, DC: National Academy Press. IOM. 2000. Clearing the Air: Asthma and Indoor Air Exposures. Washington, DC: National Academy Press. Jaakkola MS, Nordman H, Piipari R, Uitti J, Laitinen J, Karjalainen A, Hahtola P, Jaakkola JJ. 2002. Indoor dampness and molds and development of adult-onset asthma: a population-based incident case-control study. Environmental Health Perspectives 110(5): 543547. Jarvis BB. 2002. Chemistry and toxicology of molds isolated from water-damaged buildings. Advances in Experimental Medicine and Biology. 504:4352. Jarvis BB, Hinckley SF. 1999. Analysis for Stachybotrys toxins. In: Bioaerosols, Fungi and Mycotoxins: Health Effects, Assessment, Prevention and Control. Eckardt Johanning, ed. Albany, NY: Eastern New York Environmental Health Center. Jarvis JQ, Morey PR. 2001. Allergic respiratory disease and fungal remediation in a building in a subtropical climate. Applied Occupational and Environmental Hygiene 16(3):380 388. Johanning E, Landsbergis P, Gareis M, Yang CS, Olmsted E. 1999. Clinical experience and results of a sentinel health investigation related to indoor fungal exposure. Environmen- tal Health Perspectives 107(3):489494. Jussila J, Komulainen H, Huttunen K, Roponen M, Halinen A, Hyvrinen A, Kosma VM, Pelkonen J, Hirvonen MR. 2001. Inflammatory responses in mice after intratracheal instillation of spores of Streptomyces californicus isolated from indoor air of a moldy building. Toxicology and Applied Pharmacology 171(1):6169. Karagiozis AC. 2001. Advanced hygrothermal models and design models. eSim 2001--The Canadian conference on building energy simulation, June 13th14th, Ottawa, Canada. http://www.esim.ca/2001/documents/proceedings/Session3-4.pdf. Kiho T, Sakushima M, Wang SR, Nagai K, Ukai S. 1991. Polysaccharides in fungi. XXVI. Two branched (13)- -D-glucans from hot water extract of Yu er. Chemical and Phar- maceutical Bulletin 39(3):798800. Kilpelinen M, Terho EO, Helenius H, Koskenvuo M. 2001. Home dampness, current allergic diseases, and respiratory infections among young adults. Thorax 56(6):462 467. Kitamura S, Hori T, Kurita K, Takeo K, Hara C, Itoh W, Tabata K, Elgasaeter A, Stokke BT. 1994. An antitumor, branched (13)-beta-D-glucan from a water extract of fruiting bodies of Cryptoporus volvatus. Carbohydrate Research 263(1):111121.

OCR for page 29
DAMP BUILDINGS 83 Klnov K. 2000. The concentrations of mixed populations of fungi in indoor air: rooms with and without mould problems; rooms with and without health complaints. Central Euro- pean Journal of Public Health 8(1):5961. Korpi A. 2001. Fungal volatile metabolites and biological responses to fungal exposure. Kuopio University Publications C. Natural and Environmental Sciences 129. Kuopio, Finland. (PhD Thesis). Kraus J, Franz G. 1991. (13)Glucans: anti-tumor activity and immunostimulation. In: Fungal Cell Wall and Immune Response. Latge JP, Boucias D, Eds. Berlin, Heidelberg: SpringerVerlag. NATO ASI series, H53:431444. Kurnitski J. 2000. Humidity control in outdoor-air-ventilated crawl spaces in cold climate by means of ventilation, ground covers and dehumidification. Doctoral Dissertation. De- partment of Mechanical Engineering, Laboratory of Heating, Ventilating and Air Condi- tioning, Helsinki University of Technology. Report A3. Larsen TO, Frisvad JC. 1994. Production of volatiles and presence of mycotoxins in conidia of common indoor Penicillia and Aspergilli. In: Health Implications of Fungi in Indoor Environments, pp. 251279. Air Quality Monograph, Vol. 2. RA Samson, B Flannigan, ME Flannigan et al., eds. New York: Elsevier. Larsen TO, Svendsen A, Smedsgaard J. 2001. Biochemical characterization of Ochratoxin A- producing strains of the genus Penicillium. Applied and Environmental Microbiology 67(8):36303635. Lawton MD, Dales RE, White J. 1998. The influence of house characteristics in a Canadian community on microbiological contamination. Indoor Air 8:211. Li D-W, Kendrick B. 1995. A year-round study on functional relationships of airborne fungi with meteorological factors. International Journal of Biometeorology 39:7480. Liu LJ, Krahmer M, Fox A, Feigley CE, Featherstone A, Saraf A, Larsson L. 2000. Investiga- tion of the concentration of bacteria and their cell envelope components in indoor air in two elementary schools. Journal of the Air and Waste Management Association 50(11): 19571967. Lorenz W, Sigrist G, Otto H-H. 2000. Moisture indicating emissions of phthalates and their effects. Proceedings of Healthy Buildings 2000, vol. 4, Indoor Air Information, Oy, Finland. pp. 405410. Lstiburek J. 2000. Builder's Guide. Building Science Corporation. Lstiburek J. 2001. Moisture, building enclosures and mold. Part 1 of 2. HPAC Engineering. Dec.:2226. Lstiburek J. 2002a. Moisture control for buildings. ASHRAE Journal Feb.:3641. Lstiburek J. 2002b. Moisture, building enclosures and mold. Part 2 of 2. HPAC Engineering. Jan.:7781. Lstiburek J, Carmody J. 1996. Moisture Control Handbook: Principles and Practices for Residential and Small Commercial Buildings. New York: John Wiley & Sons, Inc. Lstiburek J, Pettit B. 2000. EEBA Builder's Guide: Hot-Dry/Mixed-Dry Climate (Revised). Bloomington, MN: Energy and Environmental Building Association. Lstiburek J, Pettit B. 2001. EEBA Builder's Guide: Mixed-Humid Climate (Revised). Bloomington, MN: Energy and Environmental Building Association. Lstiburek J, Pettit B. 2002a. EEBA Builder's Guide: Cold Climate (Revised). Bloomington, MN: Energy and Environmental Building Association. Lstiburek J, Pettit B. 2002b. EEBA Builder's Guide: Hot-Humid Climates (Revised). Bloomington, MN: Energy and Environmental Building Association. Martin CJ, Platt SD, Hunt SM. 1987. Housing conditions and ill health. British Medical Journal 294:11251127. Martiny H, Moritz M, Ruden H. 1994. Occurrence of Microorganisms in Different Filter Media of Heating, Ventilation and Air Conditioning (HVAC) Systems. In: Proceedings of IAQ 94-Engineering Indoor Environments. Atlanta, GA: ASHRAE. pp. 131137.

OCR for page 29
84 DAMP INDOOR SPACES AND HEALTH Meklin T, Husman T, Vepslinen A, Vahteristo M, Koivisto J, Halla-Aho J, Hyvrinen A, Moschandreas D, Nevalainen A. 2002. Indoor air microbes and respiratory symptoms of children in moisture damaged and reference schools. Indoor Air 12(3):175183. Meklin T, Hyvrinen A, Toivola M, Reponen T, Koponen V, Husman T, Taskinen T, Korppi M, Nevalainen A. 2003. Effect of building frame and moisture damage on microbiologi- cal indoor air quality in school buildings. AIHA Journal 64(1):108116. Mendell MJ, Cozen M. 2002. Building-related symptoms among U.S. office workers and risks factors for moisture and contamination: preliminary analyses of U.S. EPA BASE data. Lawrence Berkeley National Laboratory Report, LBNL-51567, Berkeley, CA. Mendell MJ, Naco GM, Wilcox TG, Sieber WK. 2003. Environmental risk factors and work- related lower respiratory symptoms in 80 office buildings: an exploratory analysis of NIOSH data. American Journal of Industrial Medicine 43(6):630641. Menzies D, Popa J, Hanley JA, Rand T, Milton DK. 2003. Effect of ultraviolet germicidal lights installed in office ventilation systems on workers' health and wellbeing: double- blind multiple crossover trial. Lancet 362(9398):17851791. Miller JD, Laflamme AM, Sobol Y, Lafontaine P, Greenhalgh R. 1988. Fungi and fungal products in some Canadian houses. International Biodeterioration 24:103120. Miller JD, Haisley PD, Reinhardt JH. 2000. Air sampling results in relation to extent of fungal colonization of building materials in some water-damaged buildings. Indoor Air 10(3):146151. Milton DK. 1999. Endotoxin and other bacterial cell-wall components. In: Bioaerosols: As- sessment and Control. Macher J, Milton DK, Burge HA, Morey P, eds. Cincinnati, OH: American Conference of Governmental Industrial Hygienists. Morey PR. 1988. Microorganisms in buildings and HVAC systems: a summary of 21 envi- ronmental studies. In: Proceedings of IAQ'88--Engineering Solutions to Indoor Air Prob- lems. Atlanta, GA: ASHRAE. pp. 1024. Morey PR. 1994. Suggested guidance on prevention of microbial contamination for the next revision of ASHRAE Standard 62. In: Proceedings of IAQ '94--Engineering Indoor Environments. Atlanta, GA: ASHRAE. pp. 139148. Morey PR, Williams CM. 1991. Is Porous Insulation Inside an HVAC System Compatible with a Healthy Building? In: Proceedings of IAQ '91Healthy Buildings, Atlanta, GA: ASHRAE. pp. 128-135. Mullins J. 2001. Microorganisms in outdoor air. In: Microorganisms in Home and Indoor Work Environments. B. Flannigan, RA Samson, JD Miller, eds. New York: Taylor & Francis. pp. 316. Murtoniemi T, Nevalainen A, Suutari M, Toivola M, Komulainen H, Hirvonen M-R. 2001. Induction of cytotoxicity and production of inflammatory mediators in RAW264.7 macrophages by spores grown in six different plasterboards. Inhalation Toxicology 13:233247. Murtoniemi T, Nevalainen A, Suutari M, Hirvonen MR. 2002. Effect of liner and core materials of plasterboard on microbial growth, spore-induced inflammatory responses and cytotoxicity in macrophages. Inhalation Toxicology 14(11):10871101. Murtoniemi T, Hirvonen MR, Nevalainen A, Suutari M. 2003a. The relation between growth of four microbes on six different plasterboards and biological activity of spores. Indoor Air 13(1):6573. Murtoniemi T, Nevalainen A, Hirvonen MR. 2003b. Effect of plasterboard composition on Stachybotrys chartarum growth and biological activity of spores. Applied and Environ- mental Microbiology 69(7):37513757. Murtoniemi T, Keinnen MM, Nevalainen A, Hirvonen MR. 2003c. Starch in plasterboard sustains Streptomyces californicus growth and bioactivity of spores. Journal of Applied Microbiology 94(6):10591065.

OCR for page 29
DAMP BUILDINGS 85 Nevalainen A, Pasanen A-L, Niininen M, Reponen T, Kalliokoski P. 1991. The indoor air quality in Finnish homes with mold problems. Environment International 17:299302. Nevalainen A, Partanen P, Jskelinen E, Hyvrinen A, Koskinen O, Meklin T, Vahteristo M, Koivisto J, Husman T. 1998. Prevalence of moisture problems in Finnish houses. Indoor Air (Supplement 4):4549. Nevander LE, Elmarsson B. 1994. Fukt handbook. Practik och teori (Moisture handbook, In Swedish). AB Svensk Byggtjnst och Frfattarna Andra, reviderade utgvan, Svenskt Tryck AB, Stockholm. Nielsen KF, Hansen M, Larsen T, Thrane U. 1998. Production of trichothecene mycotoxins in water damaged gypsum boards in Danish buildings. International Biodeterioration & Biodegradation 42:17. Nielsen KF, Gravesen S, Nielsen PA, Andersen B, Thrane U, Frisvad JC. 1999. Production of mycotoxins on artificially and naturally infested building materials. Mycopathologia 145(1):4356. Nielsen KF, Huttunen K, Hyvrinen A, Andersen B, Jarvis BB, Hirvonen MR. 2002. Metabo- lite profiles of Stachybotrys isolates from water-damaged buildings and their induction of inflammatory mediators and cytotoxicity in macrophages. Mycopathologia 154(4): 201206. Nikulin M, Pasanen A-L, Berg S, Hintikka E-L. 1994. Stachybotrys atra growth and toxin production in some building materials and fodder under different relative humidities. Applied and Environmental Microbiology 60(9):34213424. Norbck D, Bjrnsson E, Janson C, Palmgren U, Boman G. 1999. Current asthma and bio- chemical signs of inflammation in relation to building dampness in dwellings. The Inter- national Journal of Tuberculosis and Lung Disease 3(5):368376. Norbck D, Wieslander G, Nordstrm K, Walinder R. 2000. Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air. The International Journal of Tuberculosis and Lung Disease 4(11):1016 1025. Offermann FJ, Hodgson AT, Robertson JP. 2000. Contaminant emission rates from PVC backed carpet tiles on a damp concrete. Proceedings of Healthy Buildings 2000, vol. 4, Indoor Air Information, Oy, Finland. pp. 379384. Oliver A. 1997. Dampness in Buildings. Second Edition revised by James Douglas and J. Stewart Stirling. Blackwell Science Ltd. ORNL/IBP (Oak Ridge National Laboratory/ Fraunhofer Institute for Building Physics). 2003. WUFI ORNL/IBP moisture design tools for architects and engineers. http://www.ornl.gov/ sci/btc/apps/moisture/. Ottney TC. 1993. Particle Management for HVAC Systems. ASHRAE Journal 35(7):1423. Oxley TA, Gobert EG. 1994. The professionals and home owners guide to dampness in buildings, second edition. Guildford and King's Lynn, England: Biddles Ltd. Pasanen A-L. 1992. Airborne mesophilic fungal spores in various residential environments. Atmospheric Environments 26A(16):28612868. Pasanen A-L, Heinonen-Tanski H, Kalliokoski P, Jantunen MJ. 1992a. Fungal micro-colonies on indoor surfaces--an explanation for the base level fungal spore counts in indoor air. Atmospheric Environment 26B(1):121124. Pasanen A-L, Niininen M, Kalliokoski P, Nevalainen A, Jantunen MJ. 1992b. Airborne Cla- dosporium and other fungi in damp versus reference residences. Atmospheric Environ- ment 26B(1):117120. Pasanen A-L, Kasanen JP, Rautiala S, Ikheimo M, Rantamki J, Kriinen H, Kalliokoski P. 2000a. Fungal growth and survival in building materials under fluctuating moisture and temperature conditions. International Biodeterioration and Biodegradation 46(2):117127.

OCR for page 29
86 DAMP INDOOR SPACES AND HEALTH Pasanen A-L, Rautiala S, Kasanen J-P, Raunio P, Rantamki J, Kalliokosli P. 2000b. The relationship between measured moisture conditions and fungal concentrations in water- damaged building materials. Indoor Air 10(2):111120. Pearce M, Huelman PH, Janni KA, Olsen W, Seavey RT, Velsey D. 1995. Long-term moni- toring of mold contamination in flooded homes. Journal of Environmental Health 58(3):611. Peltola JSP, Andersson MA, Haahtela T, Mussalo-Rauhamaa H, Rainey FA, Kroppenstedt RM, Samson RA, Salkinoja-Salonen M. 2001a. Toxic metabolite producing bacteria and fungus in an indoor environment. Applied and Environmental Microbiology 67(7): 32693274. Peltola JSP, Andersson MA, Kmpfer P, Auling G, Kroppenstedt RM, Busse HJ, Salkinoja- Salonen M, Rainey FA. 2001b. Isolation of toxigenic Nocardiopsis strains from indoor environments and description of two new Nocardipsis species N. exhalans sp. nov. and N. umidischolae sp. nov. Applied and Environmental Microbiology 67(9):42934304. Pessi A-M, Suonketo J, Pentti M, Kurkilahti M, Peltola K, Rantio-Lehtimki A. 2002. Micro- bial growth inside insulated external walls as an indoor air biocontamination source. Applied and Environmental Microbiology 68(2):963967. Pitt JI, Basilico JC, Abarca ML, Lopez C. 2000. Mycotoxins and toxigenic fungi. Medical Mycology 38(Supplement 1):4146. Rautiala S, Reponen T, Hyvrinen A, Nevalainen A, Husman T, Vehvilinen A, Kalliokoski P. 1996. Exposure to airborne microbes during the repair of moldy buildings. American Industrial Hygiene Association Journal 57:279284. Rautiala S, Reponen T, Nevalainen A, Husman T, Kalliokoski P. 1998. Control of exposure to airborne viable microorganisms during remediation of moldy buildings; report of three case studies. American Industrial Hygiene Association Journal 59:455460. Rautiala SH, Nevalainen AI, Kalliokoski PJ. 2002. Firefighting efforts may lead to massive fungal growth and exposure within one week. A case report. International Journal of Occupational Medicine and Environmental Health 15(3):303308. Ren P, Jankun TM, Leaderer BP. 1999a. Comparisons of seasonal fungal prevalence in in- door and outdoor air and in house dusts of dwellings in one Northeast American county. Journal of Exposure Analysis & Environmental Epidemiology 9(6):560568. Ren P, Ahearn DG, Crow SA. 1999b. Comparative study of Aspergillus mycotoxin produc- tion on enriched media and construction material. Journal of Industrial Microbiology & Biotechnology 23(3):209213. Reponen T, Nevalainen A, Raunemaa T. 1989. Bioaerosol and particle mass levels and venti- lation in Finnish homes. Environment International 15:203208. Reponen T, Willeke K, Grinshpun S, Nevalainen A. 2001. Biological particle sampling. In: Aerosol measurement, Principles, techniques and applications. Second edition. Baron PA, Willeke K, eds. New York; John Wiley and Sons. pp. 751778. Reynolds SJ, Streifel AJ, McJilton CE. 1990. Elevated airborne concentrations of in residen- tial and office environments. American Industrial Hygiene Association Journal 51(11): 601604. Richard JL, Plattner RD, May J, Liska SL. 1999. The occurrence of ochratoxin A in dust collected from a problem household. Mycopathologia 146(2):99103. Roponen M, Toivola M, Meklin T, Ruotsalainen M, Komulainen H, Nevalainen A, Hirvonen M-R. 2001. Differences in inflammatory responses and cytotoxicity in RAW264.7 mac- rophages induced by Streptomyces anulatus grown on different building materials. In- door Air 11(3):179184. Rose W. 1997. Control of moisture in the modern building envelope: the history of the vapor barrier in the United States 19231952. APT Bulletin 18(4):1319.

OCR for page 29
DAMP BUILDINGS 87 Ross MA, Curtis L, Scheff PA, Hryhorczuk DO, Ramakrishnan V, Wadden RA, Persky VW. 2000. Association of asthma symptoms and severity with indoor bioaerosols. Allergy 55(8):705711. Rylander R. 2002. Endotoxin in the environment--exposure and effects. Journal of Endo- toxin Research 8(4):241252. Saito K, Nishijima M, Ohno N, Nagi N, Yadomae T, Miyazaki T. 1992. Activation of complement and limulus coagulation system by an alkali-soluble glucan isolated from Omphalia lapidescens and its less branched derivatives. Chemical and Pharmaceutical Bulletin 40:12271230. Sakurai T, Ohno N, Yadomae T. 1994. Changes in immune mediators in mouse lung pro- duced by administration of soluble (13)--D-glucan. Biological and Pharmaceutical Bulletin 17(5):617622. Salo P. 1999. Identifying and preventing fungal contamination problems in new home con- struction. In: Bioaerosols, Fungi and Mycotoxins Health Effects, Assessment, Preven- tion, and Control. E Johanning, ed. Albany, NY: New York Occupational and Environ- mental Health Center. Samson RA, Flannigan B, Flannigan ME, Verhoeff A, Adan O, Hoekstra E, eds. 1994. Health implications of fungi in indoor environments. New York: Elsevier. Sanchez H, Bush RK. 1994. Complete sequence of a cDNA encoding an Alternaria allergen. Journal of Allergy and Clinical Immunology 93:208. Schmidt M, Zargari A, Holt P, Lindbom L, Hellman U, Whitley P, van der Ploey I, Harfast B, Scheynius A. 1997. The complete cDNA sequence and expression of the first major allergenic protein of Malasseziu furfur, Mal f I. European Journal of Biochemistry 246(1): 181185. Seppnen O, Fisk WJ. 2002. Association of ventilation system type with SBS symptoms in office workers. Indoor Air 12(2):98112. Shaughnessy RJ, Levetin E, Rogers C. 1998. The Effects of UV-C on Biological Contamina- tion of AHUs in a Commercial Office Building: Preliminary Results. In: Proceedings of IAQ and Energy 98Using ASHRAE Standards 62 and 90.1. Atlanta, GA: ASHRAE. pp. 229236. Shelton BG, Kirkland KH, Flanders WD, Morris GK. 2002. Profiles of airborne fungi in buildings and outdoor environments in the United States. Applied and Environmental Microbiology 68(4):17431753. Shen HD, Liaw SF, Lin WL, Ro LH, Yang HL, Han SH. 1995. Molecular cloning of cDNA encoding for the 68 kDa allergen of Penicillium notatum using MoAbs. Clinical and Experimental Allergy 25(4):350356. Shen HD, Au LC, Lin WL, Liaw SF, Tsai JJ, Han SH. 1997. Molecular cloning and expres- sion of Penicillium citrinum allergen with sequence homology and antigenic cross- reactivity to a hsp 70 human heat shock protein. Clinical and Experimental Allergy 27(6):682690. Shen HD, Lin WL, Tam MF, Wang SR, Tsai JJ, Chou H, Han SH. 1998. Alkaline serine proteinase: a major allergen of Aspergillus oryzae and its cross-reactivity with Penicillium citrinum. International Archives of Allergy and Immunology 116(1): 2935. Sjoberg A, Nilsson L-O. 2002. Floor heating may cause IAQ problems. Proceedings of Indoor Air 1:968973. Indoor Air 2002, Inc., Santa Cruz, CA. Smart Growth in America. 1999. Rehabilitation Codes. http://wwwsmartgrowthamerica/ rehabcodes.html. Smedje G, Norbck D, Wessn B, Edling C. 1996. Asthma among school employees in rela- tion to the school environment. In: Proceedings of the Indoor Air '96 Conference, Nagoya, Japan, vol.1, Seec Ishibashi Inc., Tokyo. pp. 611616.

OCR for page 29
88 DAMP INDOOR SPACES AND HEALTH Smith JE, Moss MO. 1986. Mycotoxins Formation, Analysis, and Significance. New York: John Wiley and Sons. Sorenson WG, Frazer DG, Jarvis BB, Simpson J, Robinson VA. 1987. Trichothecene myc- otoxins in aerosolized conidia of Stachybotrys atra. Applied and Environmental Micro- biology 53(6):13701375. Spengler J, Neas L, Nakai S, Dockery D, Speizer F, Ware J, Raizenne M. 1994. Respiratory symptoms and housing characteristics. Indoor Air 4:7282. Strachan DP, Flannigan B, McCabe EM, McGarry F. 1990. Quantification of airborne moulds in the homes of children with and without wheeze. Thorax 45:382387. Straube J. 2001. Wetting, Storage and Drying Processes. Westford Symposium V. Westford, MA: Building Science Corporation. Straube J. 2002. Moisture, materials and buildings. Heating Piping and Air Conditioning Magazine. April. Straube J, Burnett E. 1997. Rain control and screened wall systems. Proceedings of the Sev- enth Building Science and Technology Conference. Toronto, Ontario. March. Su HJ, Rotnitzky A, Burge HA, Spengler JD. 1992. Examination of fungi in domestic interiors by using factor analysis: correlations and associations with home factors. Applied and Environmental Microbiology 58(1):181186. Tariq SM, Matthews SM, Stevens M, Hakim EA. 1996. Sensitization to Alternaria and Cla- dosporium by the age of 4 years. Clinical and Experimental Allergy 26:794798. TenWolde A, Rose WB. 1994. Criteria for humidity in the building and building envelope. In: Bugs, Mold & Rot II. Proceedings of a Workshop on Residential Moisture Problems, Health Effects, Building Damage, and Moisture Control. Washington, DC: National Institute of Building Sciences. Thatcher TL, Layton DW. 1995. Deposition, resuspension, and penetration of particles within a residence. Atmospheric Environment 29:14871497. Tuomi T, Reijula K, Johnsson T, Hemminki K, Hintikka E-L, Lindroos O, Kalso S, Koukila- Khkl P, Mussalo-Rauhamaa H, Haahtela T. 2000. Mycotoxins in crude building materials from water-damaged buildings. Applied and Environmental Microbiology 66(5):18991904. U.S. GAO (United States General Accounting Office). 1995. School facilities: Condition of America's Schools. Washington, DC: U.S. General Accounting Office. GAO/HEHS-95- 61. van Netten C, Shirtliffe C, Svec J. 1989. Temperature and humidity dependence of formalde- hyde release from selected building materials. Bulletin of Environmental Contamination and Toxicology 42(4):558565. Verhoeff AP, van Wijinen JH, Brunekreef B, Fischer P, van Reenen-Hoekstra ES, Samson RA. 1992. Presence of viable mould propagules in indoor air in relation to house damp and outdoor air. Allergy 47:8391. Verhoeff AP, van Wijinen JH, van Reenen-Hoekstra ES, Samson RA, van Strien RT, Brunek- reef B. 1994. Fungal propagules in house dust. II. Relation with residential characteris- tics and respiratory symptoms. Allergy 49:540547. Vesper S, Vesper MJ. 2002. Stachylysin may be a cause of hemorrhaging in humans exposed to Stachybotrys chartarum. Infection and Immunity 70(4):20652069. Vesper S, Magnuson ML, Dearborn DG, Yike I, Haugland RA. 2001. Initial characterization of the hemolysis from Stachybotrys chartarum. Infection and Immunity 69(2):912916. Viitanen H. 1994. Factors affecting the development of biodeterioration in wooden construc- tions. Materials and Structures 27:483493. Viitanen H. 1997. Modelling the time factor in the development of mould fungi--the effect of critical humidity and temperature conditions on pine and spruce sapwood. Holzfor- schung 51:614.

OCR for page 29
DAMP BUILDINGS 89 Viitanen H. 2002. Mould growth on painted wood. Seminar on Bio-deterioration of Coated Wood--Coating and Substrate, COST E18 Joint Working Group Meeting. April, Lisbon, Portugal. Waegemaekers M, van Wageningen N, Brunekreef B, Boleij JSM. 1989. Respiratory symp- toms in damp homes. Allergy 44:192198. Wlinder R, Norbck D, Wessen B, Venge P. 2001. Nasal lavage biomarkers: effect of water damage and microbial growth in an office building. Archives of Environmental Health 56(1):3036. Wang Q. 1992. Wood-based boards--Response to attack by mould and stain fungi. Doctoral dissertation. Department of Forest Products, The Swedish University of Agricultural Sciences. Sveriges lantbruksuniversitet, Istitutionen fr virkeslr, Uppsala. Wicklow DT, Shotwell OL. 1983. Intrafungal distribution of aflatoxin among conidia and sclerotia of Aspergillus flavus and Aspergillus parasiticus. Canadian Journal of Microbi- ology 29(1):15. Wickman M, Gravesen S, Nordvall SL, Pershagen G, Sundell J. 1992. Indoor viable dust- bound microfungi in relation to residential characteristics, living habits, and symp- toms in atopic and control children. Journal of Allergy and Clinical Immunology 89(3): 752759. Wieslander G, Norbck D, Nordstrm K, Wlinder R, Venge P. 1999. Nasal and ocular symptoms, tear film stability and biomarkers in nasal lavage, in relation to building- dampness and building design in hospitals. International Archives of Occupational and Environmental Health 72:451461. Williamson IJ, Martin CJ, McGill G, Monie RDH, Fennerty AG. 1997. Damp housing and asthma: a case-control study. Thorax 52:229234. Yunginger JW, Jones RT, Nesheim ME, Geller M. 1980. Studies on Alternaria allergens. III. Isolation of a major allergenic fraction (ALT-I). Journal of Allergy and Clinical Immu- nology 66(2):138147. Zhang K, Petty HR. 1994. Influence of polysaccharides on neutrophil function: Specific an- tagonists suggest a model for cooperative saccharide-associated inhibition of immune complex-triggered superoxide production. Journal of Cellular Biochemistry 56(2):225 235. Zock JP, Jarvis D, Luczynska C, Sunyer J, Burney P. European Community Respiratory Health Survey. 2002. Housing characteristics, reported mold exposure, and asthma in the European Community Respiratory Health Survey. Journal of Allergy and Clinical Immunology 110(2):285292.